Cat.6 UTP cable solid wire 23AWG Exi-Flow Exit( 1 Box:305m), Yellow – 1101-04010CH

Conductor sizes for Cat.6 are set at 23AWG

• By keeping the gauge size of the conductor larger, there is less heat generation caused and less drop of voltage over distance

• Capable of handling the latest version of power over Ethernet

• Cable has been tested over 500Mhz and has shown performance testing results allowing 10Gbit Ethernet transmission up to a length of 70mtrs

• 100Mbps, 1Gigabit & 10Gigabit Ethernet

• 155/622Mbps 1.2/2.4 Gbps ATM 550MHz

• Broadband Video | Voice; T1; ISDN

Compare Compare

The DINTEK PowerMAX500TM Cat.6 solution is guaranteed to exceed ClassE channel specifications as set down in International standards. Our PowerMAX500TM solution comprises Cat.6 component compliant patch panels, keystones and patch cords. When combined with DINTEK’s Cat.6 UTP cable, an end-to-end channel exists that maximizes data throughput and provides headroom for all future technologies operating beyond one Gigabit.

 

Construction
Conductor
Material Bare Copper
Wire Size 23AWG
Insulation
Material HDPE
Thickness Nominal: 0.226 mm
Diameter Nominal: 1.011 mm
Colors Blue/White-Blue | Orange/White-Orange | Green/White-Green | Brown/White-Brown
Unaged Elongation(%) Min. 300%
Jacket
Material Flame Retardant PVC
Thickness 0.5 ± 0.02 mm
Diameter 6.1 ± 0.2 mm
Color Yellow
Fire Rated Class CM
Physical Ranges
Insulation
Min. Tension Strength Before Aging : Min. 1.683 Kgf/mm² | After Aging : 75% before aging (100℃ x 48hrs)
Min Elongation (%) Before Aging : 300% | After Aging : 75% before aging (100℃ x 48hrs)
Jacket
Min. Tension Strength Before Aging : Min. 1.407 Kgf/mm² | After Aging : 85% before aging (100100 ℃ x 168hrs)
Min Elongation (%) Before Aging : Min. 100% | After Aging : 50 % before aging (100℃ x 168hrs)
Cold Bend Test -20 ± 2℃ x 4hrs no. crack
Dielectric Strength 2500 V dc / 2 seconds
Min. Bending Radius 50 mm
Max. Pulling Tension 25 Ibs
Installation Temperature 0℃ to +50℃
Operating Temperature -30℃ to +60℃
Electrical
Conductor Resistance Max. 7.32Ω/100m at 20℃
DC Resistance Unbalance Max. 2%
Pair-to-Ground Capacitance Unbalance 360 pF/100m
Dielectric Strength of Insulation 2500 V dc/ 2 seconds
Insulation Resistance Test Min. 5000 M Ω·Km
Mutual Capacitance Max. 5600 pF/100m
Impedance 1~100MHz 100Ω ± 15%
Impedance 100~250MHz 100 Ω ± 15%